PILOT ADJUSTING VALVES

Pilot Adjusting Valves

Manually operated gas pilot adjusting valves used to precisely control the height of a pilot flame. The throttle can be adjusted with a screw driver or a nut runner. Configurations include:

  • Single outlet, straight through design
  • Single outlet, 90° elbow design
  • Dual outlet, straight through design
  • Optional 65 micron filter screen removes impurities & particles in the gas line

Maximum operating pressure is 0.5 psig. Operating temperature range is 32°F (0°C) to 350°F (176°C). All models are design-certified by Canadian Standards Association (CSA) for use in the U.S. and Canada.

Pilot adjusting devices are shown in fully opened position.

With a flat blade screwdriver or 3/16 inch nut driver turn adjusting screw clockwise (up to 3 turns) to decrease flow.

Compression ferrules and nuts are included for all pilot adjusting devices on this page having compression connection (CC) outlets.

Straight Pilot Adjuster

pilot adjusting valves


Straight Pilot Adjuster

pilot adjuster


Straight Pilot Adjuster

pilot adjusting valve


Angled Outlet Pilot Adjuster

angled outlet pilot adjuster


Dual Outlet Pilot Adjuster

dual outlet pilot adjuster

To specify outlet size and configuration for model 6010, refer to the table below

As an example, an independently adjustable dual outlet pilot device with a dimension L=.55, a 3/16 tube connection at outlet A and 1/8 tube connection at outlet B is model 6010-32